BINDER MK1020-480V-C Series MK - Dynamic Climate Chambers, For Rapid Temperature Changes, 9020-0447
Average cooling down time according to factory standard [K/min]: 5
Average cooling down time according to IEC 60068-3-5 [K/min]: 5
Average heating-up rate according to factory standard [K/min]: 5
Average heating-up rate according to IEC 60068-3-5 [K/min]: 5.5
Cooling down time from 180 °C to -40 °C [min]: 120
Heating-up time from -40 °C to 180 °C [min]: 60
Max. heat compensation at 20 °C [W]: 6000
Temperature fluctuation [± K]: 0.1…0.5
Temperature fluctuation depending on setpoint [± K]: 0.1…0.5
Temperature range: -40…180
Temperature variation [± K]: 0.1…1.8
Temperature variation depending on setpoint [± K]: 0.1…1.8
Benefits
Homogeneous climate conditions thanks to APT.line™ technology
Comprehensive programming and data acquisition
Large heated viewing window
Important characteristics
Temperature range: -40 °C to +180 °C
APT.line™ preheating chamber technology
Programmable condensation protection for test material
Heated viewing window with LED interior lighting
BINDER Multi Management Software APT-COM™ Basic Edition
Troubleshooting system with visual and audible alarms
Intuitive touchscreen controller with time-segment and real-time programming
Internal data logger, measured values can be read out in open format via USB
Access port with silicone plug, 50 mm, left
Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
4 castors, two with brakes
Computer interface: Ethernet
Adjustable ramp function
Integrated chart recorder
Real-time clock
Door heating
1 stainless steel rack
Inner chamber made of stainless steel
CFC-free refrigerant R-452A
Cooling with compressor cooling unit
Optional equipment
APT-COM Multi Management Software – for managing, recording, and documenting unit parameters
Racks – option of stainless steel racks, depending on test requirements
Compressed air supply system
Services – wide range of services to ensure that the unit functions correctly
Technical specifications
Performance Data Temperature:
Averagecooling down time according to factory standard [K/min]: 5
Average cooling down time according to IEC 60068-3-5 [K/min]: 5
Average heating-up rate according to factory standard [K/min]: 5
Average heating-up rate according to IEC 60068-3-5 [K/min]: 5.5
Cooling down time from 180 °C to -40 °C [min]: 120
Heating-up time from -40 °C to 180 °C [min]: 60
Max. heat compensation at 20 °C [W]: 6000
Temperature fluctuation [± K]: 0.1…0.5
Temperature fluctuation depending on setpoint [± K]: 0.1…0.5
Temperature range: -40…180
Temperature variation [± K]: 0.1…1.8
Temperature variation depending on setpoint [± K]: 0.1…1.8
Electrical data
Nominal power [kW]: 11.5
Phase (Nominal voltage): 3~
Power frequency [Hz]: 60
Rated Voltage [V]: 480
Unit fuse [A]: 32
Doors
Unit doors: 1
Housing dimensions not incl. fittings and connections
Depth net [in]: 58.3
Height net [in]: 79
Width net [in]: 62.3
Internal Dimensions
Depth [in]: 31.91
Height [in]: 40.2
Width [in]: 47.3
Measures
Interior volume [cu.ft.]: 35
Load per rack [lbs]: 88
Net weight of the unit (empty) [lbs]: 1369
Permitted load [lbs]: 441
Viewing window height [in]: 11.82
Viewing window width [in]: 20.02
Wall clearance back [in]: 11.82
Wall clearance sidewise [in]: 7.88
Environment-specific data
Energy consumption at 20 °C: 1500 Wh/h
Sound-pressure level [dB(A)]: 65
Fixtures
Number of shelves (std./max.): 1/11
| Brand | BINDER |
|---|---|
| UNSPSC | 41103410 |