(713) 357-9514

BINDER CB170UL-120V-D Series CB - CO2 Incubators, With Hot Air Sterilization And Heat Sterilizable CO2 Sensor, 9640-0028

Vendor: BINDER

Mfg Part Number: 9640-0028

Be the first to review this product

Quick Overview

Recovery time after 30 seconds door open at 37 °C [min]: 6
Temperature fluctuation at 37 °C [± K]: 0.1
Temperature range +4 °C above ambient temperature to [°C]: 60
Temperature variation at 37 °C [± K]: 0.3

Price: $12205.70

Ships in 1-3 days if in stock, contact us for current availability

Quick Overview

Recovery time after 30 seconds door open at 37 °C [min]: 6
Temperature fluctuation at 37 °C [± K]: 0.1
Temperature range +4 °C above ambient temperature to [°C]: 60
Temperature variation at 37 °C [± K]: 0.3

Details









Benefits

Safe – cell cultures receive maximum protection against contamination
Reliable – constant well-being conditions for the cells
Smart – simple routine cleaning and convenient operation
Economical – efficient operation without consumables

Important characteristics

Optimized double-pan humidification system with condensation protection
Tried-and-tested anti-contamination concept with 180 °C hot air sterilization
Hot-air sterilizable CO₂ sensor with single-beam infrared technology
Seamless inner chamber made of stainless steel with flanges as shelf support system
Fanless interior with Venturi CO₂ gas mixing nozzle
Intuitive touchscreen controller
Internal data recording, can be read out in open format via USB interface
Fault diagnosis system with visual and acoustic alarm
Interfaces: Ethernet, USB, zero-voltage alarm contact
Fail-safe CO₂ system for protecting the pH of cell cultures

Optional equipment

O₂ control with O₂ control ranges: 0.2 to 20 vol.% O₂ or 10 to 95 vol.% O₂
Multi-sectional glass doors with special shelves for dividing up the space to accommodate different experiments
Stacking adapter for secure, space-saving installation
Gas tank changer for connecting two gas tanks to one or two incubators

Technical specifications

Performance Data Temperature

Recovery time after 30 seconds door open at 37 °C [min]: 6
Temperature fluctuation at 37 °C [± K]: 0.1
Temperature range +4 °C above ambient temperature to [°C]: 60
Temperature variation at 37 °C [± K]: 0.3

Performance Data Climate

Humidity range: 90…95

CO₂-Data

CO₂ measurement: IR
CO₂ range [Vol.-% CO₂]: 0…20
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min]: 5

Electrical data

Nominal power [kW]: 1.4
Phase (Nominal voltage): 1~
Power frequency [Hz]: 50/60
Rated Voltage [V]: 100…120
Unit fuse [A]: 16

Doors

Inner doors: 1
Unit doors: 1

Housing dimensions not incl. fittings and connections

Depth net [in]: 28.17
Height net [in]: 34.28
Width net [in]: 26.79

Internal Dimensions

Depth [in]: 19.9
Height [in]: 23.64
Width [in]: 22.06

Measures

Interior volume [cu.ft.]: 6
Load per rack [lbs]: 22
Net weight of the unit (empty) [lbs]: 216
Permitted load [lbs]: 66
Wall clearance back [in]: 3.94
Wall clearance sidewise [in]: 1.97

Environment-specific data

Energy consumption at 37 °C [Wh/h]: 55
Sound-pressure level [dB(A)]: 41

Fixtures

Number of shelves (std./max.): 3/6

Additional Information

Brand BINDER
Cleaning Cycle Time No
Data Export No
Door Opening No
Exterior Dimensions No
Heating No
Interior Dimensions No
Power Requirement No
Display No
Programming No
Incubator Type N/A
Temperature Range No
Number of Inner Doors No
O2 Control No
Recovery Time No
RH No
CO2 Sensor No
Number of Shelves No
Shelf Positions No
Sterilization No
Temperature Accuracy No
Temperature Uniformity No
Connectivity No