Quick Overview

Heating-up time to 150 °C [min] 18
Recovery time after 30 seconds door open at 150 °C [min]: 3
Temperature fluctuation at 150 °C [± K]: 0.3
Temperature range +5 °C above ambient temperature to [°C]: 300
Temperature variation at 150 °C [± K]: 1.5

Price: $14223.50

Ships in 24 Hours

Quick Overview

Heating-up time to 150 °C [min] 18
Recovery time after 30 seconds door open at 150 °C [min]: 3
Temperature fluctuation at 150 °C [± K]: 0.3
Temperature range +5 °C above ambient temperature to [°C]: 300
Temperature variation at 150 °C [± K]: 1.5

Details



Benefits

Uniform drying conditions thanks to APT.line™ technology
Identical test conditions throughout the chamber interior independent of sample size and quantity
Outstanding thermal insulation saves operation costs
Advanced programming options

Important characteristics

Temperature range: room temperature plus 5 °C to 300 °C
APT.line™ preheating chamber technology
Adjustable fan speed
Program-controlled ventilation flap
Color LCD controller with time-segment programming
2 chrome-plated racks
Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
Computer interface: RS 422

Technical specifications

Performance Data Temperature:

Heating-up time to 150 °C [min] 18
Recovery time after 30 seconds door open at 150 °C [min]: 3
Temperature fluctuation at 150 °C [± K]: 0.3
Temperature range +5 °C above ambient temperature to [°C]: 300
Temperature variation at 150 °C [± K]: 1.5

Air change data

Air change (approx.) at 150 °C [x/h]: 54

Electrical data

Nominal power [kW]: 3.4
Phase (Nominal voltage): 3~
Power frequency [Hz]: 50/60
Rated Voltage [V]: 400

Housing dimensions not incl. fittings and connections

Depth net [in]: 31.32
Height net [in]: 46.9
Width net [in]: 48.7

Internal Dimensions

Depth [in]: 20.09
Height [in]: 31.52
Width [in]: 39.4

Measures

Interior volume [cu.ft.]: 14.1
Load per rack [lbs]: 77
Net weight of the unit (empty) [lbs]: 381
Permitted load [lbs]: 198
Wall clearance back [in]: 6.3
Wall clearance sidewise [in]: 3.94

Environment-specific data

Energy consumption at 150 °C [Wh/h]: 1200

Fixtures

Number of shelves (std./max.): 2/10

Additional Information

Brand BINDER
UNSPSC 41104506
Cleaning Cycle Time No
Data Export No
Door Opening No
Exterior Dimensions No
Heating No
Interior Dimensions No
Power Requirement No
Display No
Programming No
Incubator Type N/A
Temperature Range No
Number of Inner Doors No
O2 Control No
Recovery Time No
RH No
CO2 Sensor No
Number of Shelves No
Shelf Positions No
Sterilization No
Temperature Accuracy No
Temperature Uniformity No
Connectivity No