Mfg Part Number
9640-0016

BINDER CB260UL-120V-O Series CB - CO2 Incubators, With Hot Air Sterilization And Heat Sterilizable CO2 Sensor, 9640-0016

Quick Overview
Recovery time after 30 seconds door open at 37 °C [min]: 6 Temperature fluctuation at 37 °C [± K]: 0.1 Temperature range +6 °C above ambient temperature to: 60 Temperature variation at 37 °C [± K]: 0.4
$20,647.60
Order will ship within 1-3 business days
Add to Wish List








Benefits

Safe – cell cultures receive maximum protection against contamination
Reliable – constant well-being conditions for the cells
Smart – simple routine cleaning and convenient operation
Economical – efficient operation without consumables

Important characteristics

Optimized double-pan humidification system with condensation protection
Tried-and-tested anti-contamination concept with 180 °C hot air sterilization
Hot-air sterilizable CO₂ sensor with single-beam infrared technology
Seamless inner chamber made of stainless steel with flanges as shelf support system
Fanless interior with Venturi CO₂ gas mixing nozzle
Intuitive touchscreen controller
Internal data recording, can be read out in open format via USB interface
Fault diagnosis system with visual and acoustic alarm
Interfaces: Ethernet, USB, zero-voltage alarm contact
Fail-safe CO₂ system for protecting the pH of cell cultures

Optional equipment

O₂ control with O₂ control ranges: 0.2 to 20 vol.% O₂ or 10 to 95 vol.% O₂
Multi-sectional glass doors with special shelves for dividing up the space to accommodate different experiments
Stacking adapter for secure, space-saving installation
Gas tank changer for connecting two gas tanks to one or two incubators

Technical specifications

Performance Data Temperature

Recovery time after 30 seconds door open at 37 °C [min]: 6
Temperature fluctuation at 37 °C [± K]: 0.1
Temperature range +6 °C above ambient temperature to: 60
Temperature variation at 37 °C [± K]: 0.4

Performance Data Climate

Humidity range: 90…95

CO₂-Data

CO₂ measurement: IR
CO₂ range [Vol.-% CO₂]: 0…20
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min]: 5

O₂-Data

O₂ control ranges with option: O₂ range [Vol.-% O₂]: 10…95
O₂ Recovery time after 30 seconds door open at 5 Vol.-% O₂ [min]: 15
Standard O₂ control ranges: O₂ range [Vol.-% O₂]: 0.2…20

Electrical data

Nominal power [kW]: 1.5
Phase (Nominal voltage): 1~
Power frequency [Hz]: 50/60
Rated Voltage [V]: 100…120
Unit fuse [A]: 16

Doors

Inner doors: 1
Unit doors: 1

Housing dimensions not incl. fittings and connections

Depth net [in]: 30.93
Height net [in]: 40.2
Width net [in]: 29.16

Internal Dimensions

Depth [in]: 22.65
Height [in]: 29.55
Width [in]: 24.43

Measures

Interior volume [cu.ft.]: 9.4
Load per rack [lbs]: 22
Net weight of the unit (empty) [lbs]: 276
Permitted load [lbs]: 88
Wall clearance back [in]: 3.94
Wall clearance sidewise [in]: 1.97

Environment-specific data

Energy consumption at 37 °C [Wh/h]: 65
Sound-pressure level [dB(A)]: 41

Fixtures

Number of shelves (std./max.): 3/8

More Information
Brand BINDER
UNSPSC 41104425