BINDER VDL023-120V Series VDL - Vacuum Drying Chambers, For Flammable Solvents, 9630-0013
Heating-up time to 100 °C [min]: 110
Temperature fluctuation [± K]: 0.1
Temperature range +10 °C above ambient temperature to [°C]: 110
Temperature range +9 °C above ambient temperature to [°C]: 110
Temperature variation at 100 °C [± K]: 1.2
Benefits
Fast, gentle drying
Optimum heat transfer through large thermal conducting plates
Safe working thanks to ATEX-compliant safety concept
Also option of modular complete system with vacuum pump and pump chamber
Important characteristics
Temperature range: +9 °C above ambient temperature to +110 °C
ATEX conformity for units: EX II 2/3/- G IIB T3 Gb/Gc/- X
Intuitive touchscreen controller with graphical pressure and temperature display
Program-controlled drying monitoring with automatic ventilation at end of process
Internal data logger, measured values can be read out in open format via USB
Pressure control device for heating activated from < 100 mbar
2 aluminum expansion racks, can be custom-positioned
Universal connection for ventilation with ambient air or inert gas
Universal access port DN 16 - for the introduction of external measuring devices
Shatterproof, spring-mounted safety glass panel
Large viewing window
Computer interface: Ethernet
Optional equipment
Expansion racks - Choice of aluminum or stainless steel racks depending on the application requirements
Analogue output for temperature and pressure signals - for external monitoring and evaluation of the process parameters, integration into in-house systems is possible
Universal ventilation - Selection of different ventilation by air or inert gas
Universal access port DN 40 - for the introduction of external measuring devices
Multi Management Software APT-COM - Manage, record and document device parameters
Services - extensive services ensure correct device function
Technical specifications
Performance Data Temperature:
Heating-up time to 100 °C [min]: 110
Temperature fluctuation [± K]: 0.1
Temperature range +10 °C above ambient temperature to [°C]: 110
Temperature range +9 °C above ambient temperature to [°C]: 110
Temperature variation at 100 °C [± K]: 1.2
Vacuum Data
Leak rate [bar/h]: 0.01
Electrical data
Nominal power [kW]: 0.9
Phase (Nominal voltage): 1~
Power frequency [Hz]: 50/60
Rated Voltage [V]: 100…120
Unit fuse [A]: 10
Connections
Measuring access port with small flange [DN mm]: 16
Universal connection for air / inert gas with flow limiter thread (RP") 3/8: 3/8
Vacuum connection with small flange [DN mm]: 16
Doors
Unit doors: 1
Housing dimensions not incl. fittings and connections
Depth net [in]: 16.27
Height net [in]: 27.5
Width net [in]: 20.61
Internal Dimensions
Depth [in]: 11.62
Height [in]: 11.23
Width [in]: 11.23
Measures
Interior volume [cu.ft.]: 0.8
Load per rack [lbs]: 44
Net weight of the unit (empty) [lbs]: 159
Permitted load [lbs]: 110
Viewing window height [in]: 12.02
Viewing window width [in]: 12.02
Wall clearance back [in]: 3.94
Wall clearance sidewise [in]: 2.76
Environment-specific data
Sound-pressure level [dB(A)]: 40
Fixtures
Number of shelves (std./max.): 2/4
| Brand | BINDER |
|---|---|
| UNSPSC | 41104509 |
| Certificate | CE |
| Heating Time | 110 min at 100 °C |
| Oven Type | Vacuum Oven |
| Temperature Uniformity | 9 °C to +110 °C |
| Heat Range | 110-100 °C |
| Temperature Accuracy | 0.1 °C |
| Shelves | 2/4 |
| Weight | 159 lbs |
| Exterior Dimensions | 16.27 x 27.5 x 20.61 in |
| Power | 120 V |
| Volume | 0.8 cu.ft |
| Interior Dimensions | 11.62 x 11.23 x 11.23 in |
| Capacity | Capacity |
| Display | analog |
| Control Type | Analog |