BINDER VDL056-120V Series VDL - Vacuum Drying Chambers, For Flammable Solvents, 9630-0014
Quick Overview
Heating-up time to 100 °C [min]: 140 Temperature fluctuation [± K]: 0.1 Temperature range +10 °C above ambient temperature to [°C]: 110 Temperature range +9 °C above ambient temperature to [°C]: 110 Temperature variation at 100 °C [± K]: 1.2
Details
Benefits
Fast, gentle drying Optimum heat transfer through large thermal conducting plates Safe working thanks to ATEX-compliant safety concept Also option of modular complete system with vacuum pump and pump chamber
Important characteristics
Temperature range: +9 °C above ambient temperature to +110 °C ATEX conformity for units: EX II 2/3/- G IIB T3 Gb/Gc/- X Intuitive touchscreen controller with graphical pressure and temperature display Program-controlled drying monitoring with automatic ventilation at end of process Internal data logger, measured values can be read out in open format via USB Pressure control device for heating activated from < 100 mbar 2 aluminum expansion racks, can be custom-positioned Universal connection for ventilation with ambient air or inert gas Universal access port DN 16 - for the introduction of external measuring devices Shatterproof, spring-mounted safety glass panel Large viewing window Computer interface: Ethernet
Optional equipment
Expansion racks - Choice of aluminum or stainless steel racks depending on the application requirements Analogue output for temperature and pressure signals - for external monitoring and evaluation of the process parameters, integration into in-house systems is possible Universal ventilation - Selection of different ventilation by air or inert gas Universal access port DN 40 - for the introduction of external measuring devices Multi Management Software APT-COM - Manage, record and document device parameters Services - extensive services ensure correct device function
Technical specifications
Performance Data Temperature:
Heating-up time to 100 °C [min]: 140 Temperature fluctuation [± K]: 0.1 Temperature range +10 °C above ambient temperature to [°C]: 110 Temperature range +9 °C above ambient temperature to [°C]: 110 Temperature variation at 100 °C [± K]: 1.2
Vacuum Data
Leak rate [bar/h]: 0.01
Electrical data
Nominal power [kW]: 1.4 Phase (Nominal voltage): 1~ Power frequency [Hz]: 50/60 Rated Voltage [V]: 100…120 Unit fuse [A]: 16
Connections
Measuring access port with small flange [DN mm]: 16 Universal connection for air / inert gas with flow limiter thread (RP") 3/8: 3/8 Vacuum connection with small flange [DN mm]: 16
Doors
Unit doors: 1
Housing dimensions not incl. fittings and connections
Depth net [in]: 18.16 Height net [in]: 32.11 Width net [in]: 25.14